Troubleshooting Guide: Error 4986 — ALTER TABLE SWITCH CLR Type Mismatch
Why This Error Happens
This error occurs when a column defined with a CLR user-defined type (UDT) in the source table does not precisely match the assembly version, type definition, or binary layout of the same-named column in the target table during a partition switch operation. SQL Server 2025 performs strict metadata validation on CLR types during ALTER TABLE...SWITCH, so even a minor discrepancy—such as a different assembly GUID, version mismatch, or a UDT registered from a different assembly build—will trigger this failure. This is commonly caused by one table referencing a CLR assembly that was redeployed, updated, or registered independently of the other, resulting in two logically similar but technically distinct type definitions.
Step-by-Step Resolution Guide
Step 1: Identify the Mismatched Column and CLR Type
- Run the following query to inspect the offending column’s type on both tables:
SELECT c.name, t.name AS type_name, t.system_type_id, t.user_type_id FROM sys.columns c JOIN sys.types t ON c.user_type_id = t.user_type_id WHERE c.object_id = OBJECT_ID('SourceTable') OR c.object_id = OBJECT_ID('TargetTable');- Confirm both columns reference the same
user_type_idand assembly name.
Step 2: Compare CLR Assembly Versions Between Tables
- Query
sys.assembliesandsys.assembly_typesto check the version, culture, and public key token of the assembly backing each UDT: SELECT a.name, a.clr_name, at.name AS type_name FROM sys.assemblies a JOIN sys.assembly_types at ON a.assembly_id = at.assembly_id;- If the source and target databases show different
clr_nameversion strings, this confirms the mismatch.
Step 3: Re-register the CLR Assembly Consistently
- Drop and re-create the UDT and its underlying assembly using the exact same
.dllfile for both tables: DROP TYPE dbo.YourUDT; DROP ASSEMBLY YourAssemblyName;CREATE ASSEMBLY YourAssemblyName FROM 'C:\SQLAssemblies\YourAssembly.dll' WITH PERMISSION_SET = SAFE;CREATE TYPE dbo.YourUDT EXTERNAL NAME YourAssemblyName.[YourUDTClass];- Re-apply this identical assembly binary across both the source and target table definitions.
Step 4: Rebuild the Column Using the Corrected Type
- Alter the column on whichever table has the outdated or mismatched type reference:
ALTER TABLE TargetTable ALTER COLUMN YourColumn dbo.YourUDT;- Ensure no open transactions or schema locks are blocking the alteration before executing.
Step 5: Retry the Partition Switch Operation
- Re-run the original command:
ALTER TABLE SourceTable SWITCH PARTITION x TO TargetTable PARTITION y;- Confirm the operation completes without raising Error 4986.
Alternative or Verification Steps
- Verify the fix by querying
sys.assembly_typeson both tables and confirming identicalassembly_idanduser_type_idvalues post-fix. - If the error persists, drop both UDT columns entirely and recreate them from a single centralized assembly deployment script to guarantee binary-level consistency across environments.