Troubleshooting Guide: Error 1104 – “No More Data Is On The Tape”
Why This Error Happens
Error 1104 occurs when a backup or restore operation reaches the physical or logical end of a tape medium (EOM) before the expected data set has been fully read or written. This is typically triggered by a corrupted tape header, a misconfigured backup job that spans multiple tapes without properly detecting the next volume, or a genuinely defective/degraded tape cartridge. It can also occur if the tape drive firmware or Windows tape driver miscommunicates the actual end-of-data marker, causing the system to prematurely flag the tape as exhausted.
Step-by-Step Resolution Guide
-
Verify Tape Drive Recognition in Windows 11
Open Device Manager (Win + X→ Device Manager) → expand Tape drives. Right-click your tape device → Update driver → Search automatically for drivers. If the driver is outdated or corrupted, reinstall it manually from the manufacturer’s site. -
Check the Tape Media Itself
Insert a different, known-good tape and attempt the same backup/restore job. If the new tape works without Error 1104, the original tape is physically worn or corrupted and should be retired. -
Run Windows Server Backup / Tape Diagnostic Utility
Open Command Prompt as Administrator and run:
wbadmin get versions
This confirms whether the backup catalog recognizes the tape’s data set boundaries correctly. If the catalog is corrupted, rebuild it via:
wbadmin delete catalog
(Note: this clears the backup catalog history — ensure you have alternate records first.)
-
Inspect and Clean the Tape Drive Hardware
Physically clean the tape drive heads using a manufacturer-approved cleaning cartridge. Dust or residue on the read/write heads is a common cause of premature EOM signals. Run the cleaning cycle, then retry the backup job. -
Adjust Backup Software Multi-Volume Settings
If using third-party backup software (Veeam, Veritas NetBackup, etc.), go to Job Settings → Media Options and ensure “Enable multi-tape spanning” or equivalent is checked. This prevents the software from stopping at Error 1104 when a job legitimately requires multiple tapes.
Alternative or Verification Steps
- Verify the fix: Run a small test backup job (a few MB) to the same tape and confirm it completes and reads back without triggering Error 1104.
- Alternative solution: If the issue persists across multiple tapes and drives, use
chkdskand Event Viewer (Windows Logs → System) to rule out a failing SCSI/SAS controller or cable connection to the tape unit, as hardware-level communication errors can also masquerade as Error 1104.