Troubleshooting Guide: Error 6274 – ALTER ASSEMBLY Serialization Format Mismatch
Why This Error Happens
This error occurs when a CLR user-defined type (UDT) or user-defined aggregate marked with Format.Native or a persisted layout is modified in a way that changes its binary serialization layout—such as reordering fields, changing data types, or altering the structure of the class. SQL Server stores persisted instances of these types (in tables, as column values) using their exact binary layout, so it blocks the ALTER ASSEMBLY operation to prevent silently corrupting existing data. This typically happens after a developer edits the .cs or .vb source of a UDT, recompiles the assembly, and attempts to deploy the update without accounting for already-persisted data in the database.
Step-by-Step Resolution Guide
Step 1: Identify Persisted Instances of the Type
- Run a query against
sys.assembly_typesto confirm which type triggered the error and check itsis_binary_orderedand format properties. - Identify all tables/columns using this UDT with a query like:
SELECT t.name AS TypeName, c.name AS ColumnName, o.name AS TableName
FROM sys.columns c
JOIN sys.types t ON c.user_type_id = t.user_type_id
JOIN sys.objects o ON c.object_id = o.object_id
WHERE t.name = 'YourUDTName';
- Export or back up this data before proceeding, as the next steps require dropping and recreating the type.
Step 2: Script Out and Drop Dependent Objects
- Generate CREATE scripts for all tables, indexes, and constraints that reference the CLR type.
- Convert affected columns to a temporary intermediate format (e.g.,
VARBINARY(MAX)usingCONVERT) to preserve the data outside the UDT structure. - Drop the dependent columns/tables, then drop the assembly using:
DROP ASSEMBLY YourAssemblyName;
Step 3: Rebuild the Assembly with Format Compatibility in Mind
- In Visual Studio or your build environment, ensure the updated class retains the original field order and types if you want to preserve
Format.Native. - If structural changes are unavoidable, switch the type’s serialization to
Format.UserDefinedand manually implementIBinarySerialize.ReadandIBinarySerialize.Writeto control versioning explicitly. - Recompile the
.dlland redeploy it using:
CREATE ASSEMBLY YourAssemblyName
FROM 'C:\Assemblies\YourAssembly.dll'
WITH PERMISSION_SET = SAFE;
Step 4: Recreate Types, Tables, and Reload Data
- Run
CREATE TYPEto re-register the UDT against the newly deployed assembly. - Recreate the original tables/columns using the scripts saved in Step 2.
- Reload the exported data, converting it back from the intermediate format into the new UDT structure using your application logic or a migration script.
Alternative or Verification Steps
- Verify the fix: After redeployment, run
ALTER ASSEMBLYagain on a test instance with a minor, non-structural code change to confirm SQL Server no longer throws Error 6274. - Alternative: If preserving the native format long-term is critical, avoid
Format.Nativeentirely for UDTs expected to evolve—useFormat.UserDefinedwith explicit versioning fields from the start to prevent this issue on future schema changes.