Why This Error Happens
Error 6232 occurs when a CLR (Common Language Runtime) user-defined type (UDT) is marked for native serialization but is being used in a context that native serialization doesn’t support, such as exceeding the 8,000-byte size limit or being referenced in operations requiring custom marshaling logic. This typically happens after assembly deployment when the Format.Native attribute was applied to a struct containing fields or properties that are incompatible with SQL Server’s native binary layout rules. It can also surface after an in-place upgrade to SQL Server 2025, where stricter CLR type validation exposes previously tolerated schema inconsistencies.
Step-by-Step Resolution Guide
Step 1: Identify the Offending Assembly and Type
- Run the following query to locate the CLR type causing the conflict:
SELECT a.name AS AssemblyName, t.name AS TypeName, t.is_binary_ordered
FROM sys.assembly_types t
JOIN sys.assemblies a ON t.assembly_id = a.assembly_id;
- Cross-reference the type name from the error message (
%.*ls.%.*ls) with this result set. - Check the assembly’s source
.csor.vbfile for the[Serializable]and[SqlUserDefinedType(Format.Native)]attributes.
Step 2: Change Serialization Format to Custom
- Open the Visual Studio project (or source file) for the CLR UDT/UDAGG.
- Modify the attribute from
Format.NativetoFormat.UserDefined:
[Serializable]
[SqlUserDefinedType(Format.UserDefined, MaxByteSize = 8000)]
public struct MyCustomType : INullable, IBinarySerialize
- Implement the
IBinarySerializeinterface (ReadandWritemethods) to manually control the byte layout, since native serialization no longer applies. - Rebuild the assembly (
.dll) using the matching .NET runtime version supported by SQL Server 2025 (currently .NET 8 CLR hosting).
Step 3: Redeploy the Assembly in SQL Server
- Drop the existing type and assembly on the instance:
DROP TYPE dbo.MyCustomType;
DROP ASSEMBLY MyAssembly;
- Re-register the updated assembly with
PERMISSION_SET = SAFE(orEXTERNAL_ACCESSif required):
CREATE ASSEMBLY MyAssembly
FROM 'C:\SQLAssemblies\MyAssembly.dll'
WITH PERMISSION_SET = SAFE;
- Recreate the UDT and any dependent tables/columns referencing it.
Step 4: Validate CLR Strict Security Settings
- Confirm
clr strict securityis enabled (default in SQL Server 2025) viasp_configure:
EXEC sp_configure 'clr strict security';
- If the assembly is unsigned, sign it with a certificate and create a corresponding login with
UNSAFE ASSEMBLYpermission, since native serialization failures can sometimes cascade from blocked trust validation.
Alternative or Verification Steps
- Verify the fix: Re-run the original INSERT/SELECT/CLR operation that triggered Error 6232; confirm no error is raised and check
sys.assembly_typesto ensureis_binary_ordered = 0(indicating custom serialization is now active). - Alternative workaround: If modifying source code isn’t immediately possible, reduce the UDT’s field footprint (remove large arrays/strings) so it stays within native serialization’s fixed-layout constraints, then redeploy without changing the
Formatattribute.